TY - JOUR
T1 - A prospective multicenter feasibility study of a miniaturized implantable continuous flow ventricular assist device in smaller children with heart failure
AU - Almond, Christopher S.
AU - Davies, Ryan
AU - Adachi, Iki
AU - Richmond, Marc
AU - Law, Sabrina
AU - Tunuguntla, Hari
AU - Mao, Chad
AU - Shaw, Fawwaz
AU - Lantz, Jodie
AU - Wearden, Peter D.
AU - Jordan, Lori C.
AU - Ichord, Rebecca N.
AU - Burns, Kristin
AU - Zak, Victor
AU - Magnavita, Ashley
AU - Gonzales, Selena
AU - Conway, Jennifer
AU - Jeewa, Aamir
AU - Freemon, D. ’Andrea
AU - Stylianou, Mario
AU - Sleeper, Lynn
AU - Dykes, John C.
AU - Ma, Michael
AU - Fynn-Thompson, Francis
AU - Lorts, Angela
AU - Morales, David
AU - Vanderpluym, Christina
AU - Dasse, Kurt
AU - Patricia Massicotte, M.
AU - Jaquiss, Robert
AU - Mahle, William T.
N1 - Copyright © 2024 International Society for the Heart and Lung Transplantation. All rights reserved.
PY - 2024/6
Y1 - 2024/6
N2 - Background: There is no FDA-approved left ventricular assist device (LVAD) for smaller children permitting routine hospital discharge. Smaller children supported with LVADs typically remain hospitalized for months awaiting heart transplant—a major burden for families and a challenge for hospitals. We describe the initial outcomes of the Jarvik 2015, a miniaturized implantable continuous flow LVAD, in the NHLBI-funded Pumps for Kids, Infants, and Neonates (PumpKIN) study, for bridge-to-heart transplant. Methods: Children weighing 8 to 30 kg with severe systolic heart failure and failing optimal medical therapy were recruited at 7 centers in the United States. Patients with severe right heart failure and single-ventricle congenital heart disease were excluded. The primary feasibility endpoint was survival to 30 days without severe stroke or non-operational device failure. Results: Of 7 children implanted, the median age was 2.2 (range 0.7, 7.1) years, median weight 10 (8.2 to 20.7) kilograms; 86% had dilated cardiomyopathy; 29% were INTERMACS profile 1. The median duration of Jarvik 2015 support was 149 (range 5 to 188) days where all 7 children survived including 5 to heart transplant, 1 to recovery, and 1 to conversion to a paracorporeal device. One patient experienced an ischemic stroke on day 53 of device support in the setting of myocardial recovery. One patient required ECMO support for intractable ventricular arrhythmias and was eventually transplanted from paracorporeal biventricular VAD support. The median pump speed was 1600 RPM with power ranging from 1–4 Watts. The median plasma free hemoglobin was 19, 30, 19 and 30 mg/dL at 7, 30, 90 and 180 days or time of explant, respectively. All patients reached the primary feasibility endpoint. Patient-reported outcomes with the device were favorable with respect to participation in a full range of activities. Due to financial issues with the manufacturer, the study was suspended after consent of the eighth patient. Conclusion: The Jarvik 2015 LVAD appears to hold important promise as an implantable continuous flow device for smaller children that may support hospital discharge. The FDA has approved the device to proceed to a 22-subject pivotal trial. Whether this device will survive to commercialization remains unclear because of the financial challenges faced by industry seeking to develop pediatric medical devices. (Supported by NIH/NHLBI HHS Contract N268201200001I, clinicaltrials.gov 02954497).
AB - Background: There is no FDA-approved left ventricular assist device (LVAD) for smaller children permitting routine hospital discharge. Smaller children supported with LVADs typically remain hospitalized for months awaiting heart transplant—a major burden for families and a challenge for hospitals. We describe the initial outcomes of the Jarvik 2015, a miniaturized implantable continuous flow LVAD, in the NHLBI-funded Pumps for Kids, Infants, and Neonates (PumpKIN) study, for bridge-to-heart transplant. Methods: Children weighing 8 to 30 kg with severe systolic heart failure and failing optimal medical therapy were recruited at 7 centers in the United States. Patients with severe right heart failure and single-ventricle congenital heart disease were excluded. The primary feasibility endpoint was survival to 30 days without severe stroke or non-operational device failure. Results: Of 7 children implanted, the median age was 2.2 (range 0.7, 7.1) years, median weight 10 (8.2 to 20.7) kilograms; 86% had dilated cardiomyopathy; 29% were INTERMACS profile 1. The median duration of Jarvik 2015 support was 149 (range 5 to 188) days where all 7 children survived including 5 to heart transplant, 1 to recovery, and 1 to conversion to a paracorporeal device. One patient experienced an ischemic stroke on day 53 of device support in the setting of myocardial recovery. One patient required ECMO support for intractable ventricular arrhythmias and was eventually transplanted from paracorporeal biventricular VAD support. The median pump speed was 1600 RPM with power ranging from 1–4 Watts. The median plasma free hemoglobin was 19, 30, 19 and 30 mg/dL at 7, 30, 90 and 180 days or time of explant, respectively. All patients reached the primary feasibility endpoint. Patient-reported outcomes with the device were favorable with respect to participation in a full range of activities. Due to financial issues with the manufacturer, the study was suspended after consent of the eighth patient. Conclusion: The Jarvik 2015 LVAD appears to hold important promise as an implantable continuous flow device for smaller children that may support hospital discharge. The FDA has approved the device to proceed to a 22-subject pivotal trial. Whether this device will survive to commercialization remains unclear because of the financial challenges faced by industry seeking to develop pediatric medical devices. (Supported by NIH/NHLBI HHS Contract N268201200001I, clinicaltrials.gov 02954497).
KW - Child
KW - Child, Preschool
KW - Feasibility Studies
KW - Female
KW - Heart Failure/therapy
KW - Heart-Assist Devices
KW - Humans
KW - Infant
KW - Male
KW - Miniaturization
KW - Prospective Studies
KW - Prosthesis Design
KW - Treatment Outcome
KW - United States
UR - https://www.scopus.com/pages/publications/85193012222
U2 - 10.1016/j.healun.2024.02.003
DO - 10.1016/j.healun.2024.02.003
M3 - Article
C2 - 38713124
AN - SCOPUS:85193012222
SN - 1053-2498
VL - 43
SP - 889
EP - 900
JO - Journal of Heart and Lung Transplantation
JF - Journal of Heart and Lung Transplantation
IS - 6
ER -