Skip to main navigation Skip to search Skip to main content

At-home end-tidal carbon dioxide measurement in children with invasive home mechanical ventilation

  • Carolyn C. Foster
  • , Soyang Kwon
  • , Avani V. Shah
  • , Caroline A. Hodgson
  • , Lindsey P. Hird-McCorry
  • , Angela Janus
  • , Aneta M. Jedraszko
  • , Philip Swanson
  • , Matthew M. Davis
  • , Denise M. Goodman
  • , Theresa A. Laguna
  • Northwestern University
  • Children's Memorial Hospital

Research output: Contribution to journalArticlepeer-review

9 Scopus citations

Abstract

Background: Carbon dioxide concentration trending is used in chronic management of children with invasive home mechanical ventilation (HMV) in clinical settings, but options for end-tidal carbon dioxide (EtCO2) monitoring at home are limited. We hypothesized that a palm-sized, portable endotracheal capnograph (PEC) that measures EtCO2 could be adapted for in-home use in children with HMV. Methods: We evaluated the internal consistency of the PEC by calculating an intraclass correlation coefficient of three back-to-back breaths by children (0–17 years) at baseline health in the clinic. Pearson's correlation was calculated for PEC EtCO2 values with concurrent mean values of in-clinic EtCO2 and transcutaneous CO2 (TCM) capnometers. The Bland–Altman test determined their level of agreement. Qualitative interviews and surveys assessed usability and acceptability by family-caregivers at home. Results: CO2 values were collected in awake children in varied activity levels and positions (N = 30). The intraclass correlation coefficient for the PEC was 0.95 (p < 0.05). The correlation between the PEC and in-clinic EtCO2 device was 0.85 with a mean difference of −3.8 mmHg and precision of ±1.1 mmHg. The correlation between the PEC and the clinic TCM device was 0.92 with a mean difference of 0.2 mmHg and precision of ±1.0. Family-caregivers (N = 10) trialed the PEC at home; all were able to obtain measurements at home while children were awake and sometimes asleep. Conclusions: A portable, noninvasive device for measuring EtCO2 was feasible and acceptable, with values that trend similarly to currently in-practice, outpatient models. These devices may facilitate monitoring of EtCO2 at home in children with invasive HMV.

Original languageEnglish
Pages (from-to)2735-2744
Number of pages10
JournalPediatric Pulmonology
Volume57
Issue number11
DOIs
StatePublished - Nov 2022
Externally publishedYes

Keywords

  • carbon dioxide
  • children with medical complexity
  • home mechanical ventilation
  • long-term mechanical ventilation
  • remote patient monitoring

Fingerprint

Dive into the research topics of 'At-home end-tidal carbon dioxide measurement in children with invasive home mechanical ventilation'. Together they form a unique fingerprint.

Cite this