T1 - Comparing hemolysis among extracorporeal pumps
T2 - A large-scale retrospective study
AU - Sousse, Linda E.
AU - Hagiwara, Junya
AU - Liu, Qianqian
AU - Maul, Timothy M.
AU - Michalek, Joel E.
AU - DellaVolpe, Jeffrey D.
N1 - Publisher Copyright:
© The Author(s) 2026. This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access page (https://us.sagepub.com/en-us/nam/open-access-at-sage).
PY - 2026
Y1 - 2026
N2 - Background: Hemolysis is a frequent and clinically relevant complication during extracorporeal life support (ECLS, or ECMO), associated with acute kidney injury, systemic inflammation, and increased mortality. Direct comparisons between pumps regarding hemolysis are limited. This study evaluated and compared hemolysis profiles among several devices in clinical practice. Methods: We conducted a retrospective, single-center cohort study adult patients who received veno-arterial (V-A) or veno-venous (V-V) ECMO between January 2020 and December 2023 (N = 230). Patients were categorized by one of four ECMO pump types, and hemolysis was assessed using lactate dehydrogenase (LDH) and plasma-free hemoglobin (pfHb) as primary markers. Multivariable linear mixed-effects models were used to analyze associations between pump type and hemolysis, adjusting for several covariates including revolutions per minute (RPM), hematologic indices, ECMO mode, and severity scores. Results: Partial thromboplastin time (p < 0.005), hemoglobin (p < 0.001), and use of continuous renal replacement therapy (CRRT, p < 0.001) were positively correlated with both LDH and pfHb concentrations and hemolysis, while fibrinogen (p < 0.03) was inversely correlated. Without RPM adjustment, NovaLung exhibited the highest LDH (680.3 U/L) and pfHb (29.4 mg/dL), followed by the Cardiohelp, Rotaflow, and CentriMag. In the RPM-adjusted analysis, LDH was highest in Cardiohelp (737.4 U/L), followed by the Rotaflow, CentriMag, and NovaLung; whereas pfHb was highest in Cardiohelp (25.8 mg/dL), followed by the Rotaflow, NovaLung, and CentriMag. Conclusions: This study provides a clinical associations of the safety and performance of four centrifugal pumps in real-world ECMO practice in adults. We demonstrate that pump-specific RPM may be potentially correlated with hemolysis during ECMO in clinical practice, illustrating that the diagonal pump, which operated at the highest RPMs, was associated with the highest hemolysis in models without the RPM adjustment. Future studies are warranted to further clarify the impact of hemolysis on outcomes.
AB - Background: Hemolysis is a frequent and clinically relevant complication during extracorporeal life support (ECLS, or ECMO), associated with acute kidney injury, systemic inflammation, and increased mortality. Direct comparisons between pumps regarding hemolysis are limited. This study evaluated and compared hemolysis profiles among several devices in clinical practice. Methods: We conducted a retrospective, single-center cohort study adult patients who received veno-arterial (V-A) or veno-venous (V-V) ECMO between January 2020 and December 2023 (N = 230). Patients were categorized by one of four ECMO pump types, and hemolysis was assessed using lactate dehydrogenase (LDH) and plasma-free hemoglobin (pfHb) as primary markers. Multivariable linear mixed-effects models were used to analyze associations between pump type and hemolysis, adjusting for several covariates including revolutions per minute (RPM), hematologic indices, ECMO mode, and severity scores. Results: Partial thromboplastin time (p < 0.005), hemoglobin (p < 0.001), and use of continuous renal replacement therapy (CRRT, p < 0.001) were positively correlated with both LDH and pfHb concentrations and hemolysis, while fibrinogen (p < 0.03) was inversely correlated. Without RPM adjustment, NovaLung exhibited the highest LDH (680.3 U/L) and pfHb (29.4 mg/dL), followed by the Cardiohelp, Rotaflow, and CentriMag. In the RPM-adjusted analysis, LDH was highest in Cardiohelp (737.4 U/L), followed by the Rotaflow, CentriMag, and NovaLung; whereas pfHb was highest in Cardiohelp (25.8 mg/dL), followed by the Rotaflow, NovaLung, and CentriMag. Conclusions: This study provides a clinical associations of the safety and performance of four centrifugal pumps in real-world ECMO practice in adults. We demonstrate that pump-specific RPM may be potentially correlated with hemolysis during ECMO in clinical practice, illustrating that the diagonal pump, which operated at the highest RPMs, was associated with the highest hemolysis in models without the RPM adjustment. Future studies are warranted to further clarify the impact of hemolysis on outcomes.
KW - extracorporeal life support
KW - extracorporeal pump
KW - hemolysis
KW - lactate dehydrogenase
KW - plasma-free hemoglobin