Skip to main navigation Skip to search Skip to main content

Pediatric chest CT diagnostic reference ranges: Development and application

  • Keith J. Strauss
  • , Marilyn J. Goske
  • , Alexander J. Towbin
  • , Debapriya Sengupta
  • , Michael J. Callahan
  • , Kassa Darge
  • , Daniel J. Podberesky
  • , Donald P. Frush
  • , Charles Maxfield
  • , Sjirk J. Westra
  • , Jeffrey S. Prince
  • , Huimin Wu
  • , Mythreyi Bhargavan-Chatfield
  • Cincinnati Children's Hospital Medical Center
  • American College of Radiology
  • Boston Children's Hospital
  • The Children's Hospital of Philadelphia
  • Duke University
  • Massachusetts General Hospital
  • Primary Children's Medical Center
  • University of Cincinnati

Research output: Contribution to journal › Article › peer-review

53 Scopus citations

Abstract

Purpose: To determine diagnostic reference ranges on the basis of the size of a pediatric patient's chest and to develop a method to estimate computed tomographic (CT) scanner-specific mean size-specific dose estimates (SSDEs) as a function of patient size and the radiation output of each CT scanner at a site. Materials and Methods: The institutional review boards of each center approved this retrospective, HIPAA-compliant, multicenter study; informed consent was waived. CT dose indexes (SSDE, volume CT dose index, and dose length product) of 518 pediatric patients (mean age, 9.6 years; male patients, 277 [53%]) who underwent CT between July 1, 2012, and June 30, 2013, according to the guidelines of the Quality Improvement Registry in CT Scans in Children were retrieved from a national dose data registry. Diagnostic reference ranges were developed after analysis of image quality of a subset of 111 CT examinations to validate image quality at the lower bound. Pediatric dose reduction factors were calculated on the basis of SSDEs for pediatric patients divided by SSDEs for adult patients. Results: Diagnostic reference ranges (SSDEs) were 1.8-3.9, 2.2-4.5, 2.7-5.1, 3.6-6.6, and 5.5-8.4 mGy for effective diameter ranges of less than 15 cm, 15-19 cm, 20-24 cm, 25-29 cm, and greater than or equal to 30 cm, respectively. The fractions of adult doses (pediatric dose reduction factors) used within the consortium for patients with lateral dimensions of 8, 11, 14, 17, 20, 23, 26, 29, 32, 35, and 38 cm were 0.29, 0.33, 0.38, 0.44, 0.50, 0.58, 0.66, 0.76, 0.87, 1.0, and 1.15, respectively. Conclusion: Diagnostic reference ranges developed in this study provided target ranges of pediatric dose indexes on the basis of patient size, while the pediatric dose reduction factors of this study allow calculation of unique reference dose indexes on the basis of patient size for each of a site's CT scanners.

Original languageEnglish
Pages (from-to)219-227
Number of pages9
JournalRadiology
Volume284
Issue number1
DOIs
StatePublished - Jul 2017

Fingerprint

Dive into the research topics of 'Pediatric chest CT diagnostic reference ranges: Development and application'. Together they form a unique fingerprint.

Cite this