Skip to main navigation Skip to search Skip to main content

Pediatric tibial eminence fracture treatment: A case series using a bioabsorbable screw

  • M. Wesley Honeycutt
  • , Anna J. Rambo
  • , Daniel P. Zieman
  • , Prasit Nimityongskul
  • University of South Alabama

Research output: Contribution to journalArticlepeer-review

8 Scopus citations

Abstract

Background: Pediatric tibial eminence fractures constitute a complex injury with multiple treatment options. We have described a technique that combines direct visualization through an open approach and stable fixation using a bioabsorbable screw. The purpose of this study is to describe our surgical technique for tibial eminence fractures and to compare the radiographic and functional outcomes to previous open or arthroscopic methods. Methods: We retrospectively reviewed a series of five pediatric patients who underwent open reduction and internal fixation of a tibial eminence fracture with a headless, bioabsorbable poly-L lactic acid (PLLA) screw (Bio-Compression screw, Arthrex Inc, Naples, FL) from 2016 to 2017. The surgical technique involves an open approach, direct fracture reduction, and fixation with a PLLA screw without violating the epiphyseal plate. Postoperative assessment was quantified using the Lysholm knee score (LKS), knee arc of motion (AOM), presence of a pivot shift or Lachman, and knee radiographs with an average of 18.4 months of follow-up. Results: Five patients (average age of 11.3 years) were treated with a biobsorbable screw and followed for an average of 18.4 months. Average LKS was 99.6, AOM was 98.4%, all patients had negative pivot shift and Lachman exams, and all patients went on to radiographic union. No patients required re-operation or implant removal. Conclusions: The goals of tibial eminence fracture management are fracture union, restoring knee stability, and regaining normal knee motion and kinematics. Our study demonstrates that open treatment with a bioabsorbable screw is an excellent alternative surgical method as it reliably results in rigid fixation, fracture union, excellent knee function scores, and it mitigates the possible need for hardware removal. Level of evidence: Therapeutic Level IV – Case series.

Original languageEnglish
Pages (from-to)S675-S680
JournalJournal of Clinical Orthopaedics and Trauma
Volume11
DOIs
StatePublished - Jul 2020

Keywords

  • Bioabsorbable screw
  • Open treatment
  • Tibial eminence

Fingerprint

Dive into the research topics of 'Pediatric tibial eminence fracture treatment: A case series using a bioabsorbable screw'. Together they form a unique fingerprint.

Cite this