Skip to main navigation Skip to search Skip to main content

Use of an Enuresis Alarm to Guide Timing of Post-Void Residual Volume Assessment in Infants and Medically-Complex, Non-Verbal Children

  • Peter Y. Cai
  • , Andrea Balthazar
  • , Regina L. Tham
  • , Badar Omar
  • , Sangeeta Mauskar
  • , Walter Wickremasinghe
  • , Bartley G.J. Cilento
  • , Caleb P. Nelson
  • Boston Children's Hospital

Research output: Contribution to journal › Article › peer-review

1 Scopus citations

Abstract

Objective: To test the feasibility and efficacy of using an enuresis alarm to guide the timing of post-void residual (PVR) measurement in two different cohorts of non-verbal, non-toilet trained pediatric patients. Methods: We prospectively enrolled 15 infants (Group 1) and 15 medically-complex patients (Group 2) to undergo an 8-hour study period that included a 4-hour intervention period with alarm (PVR after alarm trigger) and a 4-hour control period of routine care (PVR when nurses observe wet diapers). The primary endpoint of PVR volume was analyzed using linear regression with volume as the dependent variable and both study period and patient weight as independent variables. Secondary endpoint of the number of detected voids was analyzed using Mann-Whitney U test. Results: In Group 1, the median number of voids detected was significantly greater in the alarm versus routine care periods (3 vs 2, P = .0029). Use of alarm was associated with a non-significant mean decrease of 2.23 mL (95% CI −7.09 to 2.63, P = .363) in PVR volume for infants. In Group 2, the median number of detected voids were also significantly different in the alarm versus routine care periods (3 vs 1, P = .0312). Use of alarm was associated with a mean decrease of 21.09 mL (95% CI −40.60 to −1.58, P = .035) in PVR volume. Conclusion: An enuresis alarm facilitated detecting significantly more voids in both infants and medically-complex, non-verbal children and was also associated with a decrease in PVR volume in the latter group. Such use of enuresis alarms may prove useful to measure PVR more accurately in these challenging populations.

Original languageEnglish
Pages (from-to)125-129
Number of pages5
JournalUrology
Volume198
DOIs
StatePublished - Apr 2025
Externally publishedYes

Fingerprint

Dive into the research topics of 'Use of an Enuresis Alarm to Guide Timing of Post-Void Residual Volume Assessment in Infants and Medically-Complex, Non-Verbal Children'. Together they form a unique fingerprint.

Cite this