Ir directamente a la navegación principal Ir directamente a la búsqueda Ir directamente al contenido principal

Barriers and facilitators of CT scan reduction in the workup of pediatric appendicitis: A pediatric surgical quality collaborative qualitative study

  • Andrew Hu
  • , Azraa S. Chaudhury
  • , Terry Fisher
  • , Elisa Garcia
  • , Loren Berman
  • , Kuojen Tsao
  • , Anne Mackow
  • , Stephen B. Shew
  • , Julie Johnson
  • , Shawn Rangel
  • , Kevin P. Lally
  • , Mehul V. Raval
  • Northwestern University
  • University of Texas Health Science Center at Houston
  • Thomas Jefferson University
  • Case Western Reserve University
  • Stanford University
  • Boston Children's Hospital

Producción científica › revisión exhaustiva

24 Citas (Scopus)

Resumen

Introduction: Despite ongoing efforts to decrease ionizing radiation exposure from computed tomography (CT) use in pediatric appendicitis, high CT utilization rates are still observed across many hospitals. This study aims to identify factors influencing CT use and facilitators and barriers to quality improvement efforts. Methods: The Pediatric Surgery Quality Collaborative is a voluntary consortium of 42 children's hospitals participating in the National Surgical Quality Improvement Project - Pediatric. Hospitals were compared based on CT utilization from January 1, 2019, to December 31, 2019. Semi-structured interviews were conducted with surgeons, radiologists, emergency medicine physicians, and clinical data abstractors from 7 hospitals with low CT use rates (high performers) and 6 hospitals with high CT use rates (low performers). A mixed deductive and inductive coding approach for analysis of the interview transcripts was used to develop a codebook based on the Theoretical Domains Framework and subsequently identify prominent barriers and facilitators to CT reduction. Results: Thematic saturation was achieved after 13 interviews. We identified four factors that distinguish high-performing from low-performing hospitals: (1) consistent availability of resources such as ultrasound technicians, pediatric radiologists, and magnetic resonance imaging (MRI); (2) presence of and adherence to protocols guiding imaging modality decision making and imaging execution; (3) culture of inter-departmental collaboration; and (4) presence of a radiation reduction champion. Conclusions: Significant barriers to reducing the use of CT in pediatric appendicitis exist. Our findings highlight that future quality improvement efforts should target resource availability, protocol adherence, collaborative culture, and radiation reduction champions.

Idioma originalEnglish
Páginas (desde-hasta)582-588
Número de páginas7
PublicaciónJournal of Pediatric Surgery
Volumen57
N.º11
DOI
EstadoPublished - nov 2022
Publicado de forma externaSí

Huella

Profundice en los temas de investigación de 'Barriers and facilitators of CT scan reduction in the workup of pediatric appendicitis: A pediatric surgical quality collaborative qualitative study'. En conjunto forman una huella única.

Citar esto