Ir directamente a la navegación principal Ir directamente a la búsqueda Ir directamente al contenido principal

Evaluation of tissue saturation as a noninvasive measure of mixed venous saturation in children

  • Richard J. Levy
  • , Whitney B. Stern
  • , Kimberly I. Minger
  • , Lisa M. Montenegro
  • , Chitra Ravishankar
  • , Jonathan J. Rome
  • , Susan C. Nicolson
  • , David R. Jobes
  • The Children's Hospital of Philadelphia

Producción científica › revisión exhaustiva

14 Citas (Scopus)

Resumen

Background: Mixed venous saturation (SV̄O2) is an important measurement that helps guide the care of critically ill patients. Invasive SV̄O2 assessment in infants and children is often avoided because of the inherent risks. A noninvasive tissue saturation (STO2) monitor has recently been developed that uses near-infrared spectroscopy to measure oxyhemoglobin saturation in muscle. In adult and animal studies, STO2 correlated with oxygen delivery and SV̄O2. There has been no evaluation in pediatric patients. Objective: To evaluate tissue saturation as a noninvasive measure of mixed venous saturation in children. Design: A prospective observational study. Setting: Catheterization laboratory in a tertiary care children's medical center. Patients: We studied 98 children (49 without intracardiac mixing and 49 with intracardiac mixing) ≤12 yrs of age who underwent cardiac catheterizatlon. Under general anesthesia, we compared STO2 measured over the deltoid muscle with superior vena cava saturation in both groups and STO2 with pulmonary artery saturation in patients without intracardiac mixing. Paired measurements were analyzed for bias, precision, and correlation via Bland-Altman plot and linear regression. Resulte: No meaningful correlation was found between STO2 and superior vena cava saturation or pulmonary artery saturation. Bland-Altman analyses of STO2 with superior vena cava saturation yielded bias values of -6.67 ± 37.33% in patients with intracardiac mixing and -0.82 ± 41.31% in patients without mixing. Bland-Altman analysis of STO 2 with pulmonary artery saturation yielded a bias of 3.61 ± 41.32% in patients without mixing. Differences between noninvasive and invasive measurements were greatest in smaller children. Conclusion: Noninvasive tissue saturation over the deltoid does not correlate with SV̄O2 in children. It is possible that more precise probe spacing, coupled with optimal muscle-mass location, could result in more accurate measures in future investigations.

Idioma originalEnglish
Páginas (desde-hasta)671-675
Número de páginas5
PublicaciónPediatric Critical Care Medicine
Volumen6
N.º6
DOI
EstadoPublished - nov 2005
Publicado de forma externaSí

Huella

Profundice en los temas de investigación de 'Evaluation of tissue saturation as a noninvasive measure of mixed venous saturation in children'. En conjunto forman una huella única.

Citar esto