Ir directamente a la navegación principal Ir directamente a la búsqueda Ir directamente al contenido principal

Real-time physical activity detection module during sensor augmented insulin pump therapy

  • Eleonora Manzoni
  • , Emilia Fushimi
  • , Eleonora M. Aiello
  • , Zoey Li
  • , Robin Gal
  • , Corby K. Martin
  • , Susana R. Patton
  • , Simone Del Favero
  • , Francis J. Doyle
  • University of Padua
  • Harvard University
  • Universidad Nacional de La Plata
  • Sansum Diabetes Research Institute
  • Jaeb Center for Health Research
  • LSU Pennington Biomedical Research Center

Producción científicarevisión exhaustiva

Resumen

Individuals living with type 1 diabetes (T1D) face important challenges when engaging in physical activity (PA), as it necessitates careful management of blood glucose levels often through insulin adjustments and carbohydrate intake. Integrating PA detection into sensor augmented insulin pumps (SAP) is a promising strategy to enhance glycemic control by suggesting basal insulin reduction or carbohydrate ingestion in the critical 24 h after the PA detection.We have developed a real-time, model-based module for PA detection based solely on measured glucose levels, insulin infusion rates, and carbohydrate intake. The approach is based on the monitoring of the magnitude as well as various statistical properties of the prediction residuals, i.e., the discrepancies between actual sensor-measured glucose levels and model-predicted levels.We tested our algorithm on the Type 1 Diabetes and Exercise Initiative (T1DEXI) dataset, which includes structured sessions of aerobic, resistance, and interval exercises. In a dataset containing all three activity types, the detection approach based on the median of the prediction residuals successfully detected an average of 59% of PA instances, while keeping the false alarms to 3.5 per considered timeframe, when considering models tailored to each participant. When using a population model identified on in-silico data from the UVa/Padova T1D simulator, the approach successfully detected 62% of PAs, while keeping the false alarms to 3.6 per considered timeframe.These encouraging findings open the possibility of integrating PA detection into SAP systems without the need for additional physiological signals, thus enabling improved glucose management.

Idioma originalEnglish
Número de artículo103608
PublicaciónJournal of Process Control
Volumen157
DOI
EstadoPublished - ene 2026

Huella

Profundice en los temas de investigación de 'Real-time physical activity detection module during sensor augmented insulin pump therapy'. En conjunto forman una huella única.

Citar esto