Resumen
Introduction: Left ventricular end-diastolic volume (LVEDV) calculation is important in decision making in children with congenital heart disease (CHD). This study examined the accuracy of LVEDV calculation by the formula: 5/6 × area × length ("bullet" method), by comparing echocardiographic (ECHO) LVEDV against cardiac magnetic resonance (CMR). Methods: ECHO and CMR data from 72 consecutive subjects with CHD ≤10 years of age were retrospectively reviewed. Exclusion criteria included: >3 months between examinations; unavailable or poor-quality images. Subxiphoid short- and long-axis echocardiographic images were analyzed. Bullet LVEDV was compared to CMR volumes. Results: Seventeen subjects (median age 5.5 years, range 1-10 years) comprised the study group. ECHO and CMR LVEDV showed an excellent correlation (r = 0.97) and a good agreement with a mean difference (limits of agreement) of -1.0 mL (-13.9 to 11.9 mL). Conclusions: Subxiphoid echocardiographic bullet method of measuring LVEDV shows a good agreement with CMR obtained LV size in young children.
| Idioma original | English |
|---|---|
| Páginas (desde-hasta) | 691-695 |
| Número de páginas | 5 |
| Publicación | Echocardiography |
| Volumen | 27 |
| N.º | 6 |
| DOI | |
| Estado | Published - jul 2010 |
| Publicado de forma externa | Sí |
Huella
Profundice en los temas de investigación de 'The accuracy of echocardiographic assessment of left ventricular size in children by the 5/6 area × length (bullet) method'. En conjunto forman una huella única.Citar esto
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver